PV Powered 5200 Manuale

Navigare online o scaricare Manuale per Alimentatori e invertitori PV Powered 5200. PV Powered 5200 Product manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - SAMIL POWER

SP-SR-V8-ENSolarRiver PV Grid-tied InverterProduct Manual SAMIL POWERExpert for PV Grid-tied InvertersTMEnglish

Pagina 2

08Introduction ● Dimension● Weight 3.3 Dimensions and Weight Figure 6 SolarRiver 1100TL/SolarRiver 1600TLFigure 7 SolarRiver 2300TL/SolarRiver 3

Pagina 3 - Copyright Declaration

ModelMax.DC power [W]Max.DC voltage [V]Max. input current [A]Number of MPP trackers/ Strings per MPP trackersMPPT voltage range (at rated powe) [V]Shu

Pagina 4 - CONTENTS

Ground fault protectionGrid monitoringGround fault current monitoringDC injection monitoringYesYesYesYesContinued:4.4 General DataModelDimensions (W

Pagina 5 - 2 Safety

11Installation 6 Installation 6.1 PackagingType Project No. Description QTY Remark Equipment 1 PV Grid-tied Inverter 1 unitInstallation Kit f

Pagina 6 - 2.3 Explanation of Symbols

12InstallationSolarRiver 1100TL~1600TL Inverter Backboard SolarRiver 2300TL~5200TL Inverter BackboardWarning!Ensure that the DC side is not charged b

Pagina 7 - Symbol Explanation

13InstallationStep1: Drill holes in the wall with drill machine according to the size of bracket. Drill straight into the wall do not shake the drill

Pagina 8 - 3 Introduction

14InstallationStep3Step2Step5Step4Step2: Clean all dust outside/inside the hole and ensure the distances between hole are as per requirement.Insert ex

Pagina 9 - Caution!

Installation6.5 Connections of the PV power system Step3: Use the bracket to install the inverter onto the narrow vertical panel (or wall). Ensure

Pagina 10 - 3.3 Dimensions and Weight

16InstallationNote! Need not connect the input terminal to optimizer.● AC OutputSolarRiver series inverters are designed for single phase grid. Op

Pagina 11 - 4 Technical Data

17InstallationFigure 14 AC Connector details SolarRiver 2300TL~5200TL SolarRiver 1100TL~1600TLSocket elementThread sleevewith sealing ring10-14mmsea

Pagina 13 - 6 Installation

18InstallationStep3: Confirm that all the wires are fixed tightly( Figure 17).Step4: Fix the threaded sleeve (Figure 18).Figure 17Thread sleeveSocket

Pagina 14 - Note!

6.6 Inverter Start-up• Only start inverter after checking following• Starting invertera. Make sure all the DC and AC breakers and Isolators are i

Pagina 15 - 6.4 Installation Steps

7.2 Display FunctionThe function key is used to set the LCD. It can alternate between different parameters and languages.20OperationDisplay on norma

Pagina 16 - Step5Step4

21Operation Normal State Pac=xxxx.xW Etotal=xx.xkwh Pac=xxxx.xW Etoday=.xxxx.xkwhPac=xxxx.xW Ipv=xx.xA Pac=xxxx.xW Vac=x

Pagina 17

22OperationLockup function as below: Set language as below: Select language Pac=xxxx.xW Udc=xx.xV Pac=xxxx.xW Lock Pac=xxxx.x Udc=

Pagina 18

Operation23Fault InformationOthersOutput Voltage Vac=xxx.xVOutput Frequency Freq.=xx.xHzOutput Current Iac=xx.xAPV Input Voltage Vpv= xxxVPV Input Cur

Pagina 19 - Figure 15

Communication and Monitoring248 Communication and Monitoring8.1 Communication Interface8.2 Communication typesSolarRiver inverters have communi

Pagina 20 - Pressure screw

Communication and Monitoring25Figure 24 SolarLog Monitoring DiagramFigure 25 Inverter wiringFigure 26 SolarLog WiringTwo types of cable must be pre

Pagina 21 - 7 Operation

Troubleshooting269 Troubleshooting9.1 TroubleshootingThis section contains information and procedures for solving possible problems on

Pagina 22 - 7.2 Display Function

Troubleshooting27Continued:Fan Fault - Check the fan for any block.- Check fan cables.- If fault persists, contact Samil Power for assistance.High DC

Pagina 23 - Operation

Copyright DeclarationThe copyright of this manual belongs to Samil Power Co., Ltd. Any corporation or individual should not plagiarize, partially copy

Pagina 24 - 7.3 Display information

Decommissioning & Contacting Samil Power2810.1 Dismantling the Inverter10.2 Packaging10.3 Storage10.4 DisposalIf possible, pack the invert

Pagina 26 - 8.2 Communication types

Marketing & Sales OfficeAdd: No.52,Huigu Innovation Park, Huishan District, Wuxi,Jiangsu Province,P.R.China 214174Tel: +86 510

Pagina 28 - 9 Troubleshooting

031 NotesDanger!Danger indicates a hazardous situation, if not avoided, will result in death or serious injury.1.1 Scope of Validity2 Safety2.

Pagina 29 - 9.2 Routine Maintenance

04This section gives an explanation of all the symbols shown on the inverter and on the type label.The appliance is not to be used by children or pers

Pagina 30 - 11 Contacting Samil Power

05Symbol Explanation5 minDanger to life due to high voltages in the inverter!There is residual voltage in the inverter. The inverter requires

Pagina 31

06Do not disassemble the SolarRiver Series inverter. It contains no user-serviceable parts. See warranty for instructions on obtaining service. Attemp

Pagina 32 - SAMIL POWER CO., LTD

07Introduction ● Terminals on the inverter Caution!SF-SW. Risk of electric shock!Only authorized personnel is allowed to set the DIP switch.RS232DC